Key Features of Time And Frequency Synchronization Platform
  • Field-upgradeable and flexible system that covers all synchronization requirements
  • Has four power supply slots, two clock module slots, a seamless switchover card slot, a CPU slot and ten slots for additional input and output modules
  • Optimized space usage
  • Web based status and configuration interface and console based graphical configuration utility
  • IMS - Intelligent Modular System platform
  • Up to 10 PTP (IEEE 1588-2008) modules
  • Redundant power and receiver option ( like GPS)
  • Hot Plug
  • Arbitrary combinations of modules
  • Time server can be provided with a large number of additional output options: IRIG Time Code, frequency synthesizer and programmable pulse outputs are only a few of the many expansion options for NTP server
  • Up to 40 additional LAN ports
Enquire now
Product Profile of Time And Frequency Synchronization Platform
Time and Frequency Synchronization Platform is a field-upgradeable and flexible system that covers all synchronization requirements. The Synchronization Platform has four power supply slots, two clock module slots, a seamless switchover card slot, a CPU slot and ten slots for additional input and output modules. The Time and Frequency Synchronization Platform is featured with web based status and configuration interface and console based graphical configuration utility. Time and Frequency Synchronization Platform is available with up to 40 additional LAN ports.

Paryana Automation Pvt. Ltd offers Time and Frequency Synchronization Platform, manufactured by Meinberg, Germany. Paryana Automation Pvt. Ltd is the supplier of automation and integration solutions such as NTP server, time and frequency synchronization platform, slot card for computers, NTP time server and ethernet data logger.

Key Features of Time And Frequency Synchronization Platform
  • Field-upgradeable and flexible system that covers all synchronization requirements
  • Has four power supply slots, two clock module slots, a seamless switchover card slot, a CPU slot and ten slots for additional input and output modules
  • Optimized space usage
  • Web based status and configuration interface and console based graphical configuration utility
  • IMS - Intelligent Modular System platform
  • Up to 10 PTP (IEEE 1588-2008) modules
  • Redundant power and receiver option ( like GPS)
  • Hot Plug
  • Arbitrary combinations of modules
  • Time server can be provided with a large number of additional output options: IRIG Time Code, frequency synthesizer and programmable pulse outputs are only a few of the many expansion options for NTP server
  • Up to 40 additional LAN ports
Product Specification of Time And Frequency Synchronization Platform
  • Accuracy: Accuracy of pulse outputs - < ?100ns.
  • Ambient Temperature: 0 - 50 &deg;C / 32 - 122&deg;F.
  • Control: Control elements - Eight push buttons to set up basic network parameters and to change system settings.
  • Display: LC-display, 4 x 16 characters.
  • Firmware: Firmware Updates - Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection. Software updates are provided free of charge, for the lifetime of your Meinberg product.
  • Form Factor: Rackmount 3U chassis for standard 19" racks.
  • Frequency: Frequency outputs - Accuracy depends on oscillator (standard: OCXO-MQ).
  • Humidity: Max. 85%
  • Interface: Network Interface : Basic Chassis: 1 x 10/100 MBit with RJ45 connector, Network Expansion - LNE Options: Up to a maximum of 40 additional 10/100/1000Mbps (GbE Gigabit support) network interfaces with RJ45 connector.
  • Operating System: Operating System of the SBC : GNU/Linux 3.x.
  • Ports: Universal Serial Bus (USB) Ports : 1x USB Port in front panel: - install firmware upgrades, backup and restore configuration files, copy security keys, lock/unlock front keys.
  • Power Consumption: 50W (max. 100W)
  • Power Supply: 100-240 V AC (50/60 Hz) / 100-240 V DC, Redundant Power Supplies and other DC input voltage ranges available upon request.
  • Protocol: Network Time Protocol (NTP) : NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905), SNTP v3 (RFC 1769), SNTP v4 (RFC 2030), MD5 Authentication and Autokey Key Management; Time Protocol (TIME) : Time Protocol (RFC 868) ; Daytime Protocol (DAYTIME) : Daytime Protocol (RFC 867) ; Hypertext Transfer Protocol (HTTP) : HTTP/HTTPS (RC 2616) ; Simple Network Management Protocol (SNMP) : SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418).
  • Supply: Scope of supply - Product documentation and software on USB storage device.
  • Support: Network Autoconfiguration Support : IPv4: Dynamic Host Configuration Protocol - DHCP (RFC 2131), IPv6: Autoconfiguration Networking - AUTOCONF ; Technical Support - Meinberg offers free lifetime technical support via telephone or e-mail.
  • Warranty/Guarantee: Three-Year Warranty.