1 Ad

Thermoplastic Softening Temperature Equipment

Supplier : Pressmex Hydraulics

Key Features of Thermoplastic Softening Temperature Equipment
  • Comes with the feature of setting the required temperature recommended for the specific material to be tested.
  • The indent rod to be inserted and the indent point should be resting over the test sample.
  • The total load of dead weight is applied on test sample
  • Comes with the feature that the dial gauge should be set at zero to measure movement of indent rod downward.
  • As the temperature in bath increases gradually and a constant pressure on indenter is applied, the indenter pin will start penetrating test sample. This movement of penetration of indent pin can be read on the dial gauge with accuracy of 0.01 mm.
  • Simultaneously the temperature of the test sample is read on temperature controller on the panel with accuracy of 0.1 c.
Enquire now
Product Profile of Thermoplastic Softening Temperature Equipment
Thermoplastic Softening Temperature Equipment comes with the feature of setting the required temperature recommended for the specific material to be tested. The Temperature Equipment requires the indent rod to be inserted and the indent point should be resting over the test sample. The Temperature Equipment ensures that the total load of dead weight is applied on test sample. The Thermoplastic Softening Temperature Equipment comes with the feature that the dial gauge should be set at zero to measure movement of indent rod downward.

Pressmex Hydraulics manufactures Thermoplastic Softening Temperature Equipment. Pressmex Hydraulics also offers a wide range of hydraulic machineries like hydraulic/ hydrostatic pressure testing machines, impact test machine, pipe end caps, bottle thickness measuring equipments, lab deep freezer, humidity chambers, opacity/ transparency testing apparatus, constant temperature bath, lab oven etc.

Key Features of Thermoplastic Softening Temperature Equipment
  • Comes with the feature of setting the required temperature recommended for the specific material to be tested.
  • The indent rod to be inserted and the indent point should be resting over the test sample.
  • The total load of dead weight is applied on test sample
  • Comes with the feature that the dial gauge should be set at zero to measure movement of indent rod downward.
  • As the temperature in bath increases gradually and a constant pressure on indenter is applied, the indenter pin will start penetrating test sample. This movement of penetration of indent pin can be read on the dial gauge with accuracy of 0.01 mm.
  • Simultaneously the temperature of the test sample is read on temperature controller on the panel with accuracy of 0.1 c.
3 Ad

2 Ad