Battery-Powered Dielectric Fault Analyzer

Supplier : Doble Engineering Pvt. Ltd.

Key Features of Battery-Powered Dielectric Fault Analyzer
  • Condition-Based Monitoring. Use for GIS, SF6-filled dead-tank breakers, and instrument transformers, during commissioning and in service. Identify and locate PD, particles, and mechanical defects.
  • Rapid Results. Is quick and easy to configure, producing results in seconds. Use the results by themselves or in conjunction with other in-service test results to assist decision making.
  • Selectable Settings. Provides recommended settings for testing both SF6-filled and oil-filled equipment.
  • Simple, User-Friendly PC Interface. Use the simple interface to upload test results to a PC or download previous data and nameplate configurations.
  • Rugged and Reliable. Has outstanding durability for field use and produces high-quality results with high repeatability, allowing for rapid and reliable decisions.
  • Wireless Synchronization. The DFA100 uses a wireless synchronization module for timing PD and mechanical activity against the power system frequency.
Enquire now
Product Profile of Battery-Powered Dielectric Fault Analyzer
Doble Engineering Private Ltd manufactures Battery-Powered Dielectric Fault Analyzer. Doble Engineering Private Ltd is an ISO 9001:2000 certified company. Doble Engineering Private Ltd also offers different types of supplying diagnostic instruments, services. Battery-Powered Dielectric Fault Analyzer is ideal for monitoring non-intrusive, in-service acoustic signals produced by partial discharge and loose components. It is designed to detect faults in grounded SF6 gas-insulated systems, such as SF6-filled dead-tank circuit breakers and can also be applied to grounded oil-filled instrument transformers.

Key Features of Battery-Powered Dielectric Fault Analyzer
  • Condition-Based Monitoring. Use for GIS, SF6-filled dead-tank breakers, and instrument transformers, during commissioning and in service. Identify and locate PD, particles, and mechanical defects.
  • Rapid Results. Is quick and easy to configure, producing results in seconds. Use the results by themselves or in conjunction with other in-service test results to assist decision making.
  • Selectable Settings. Provides recommended settings for testing both SF6-filled and oil-filled equipment.
  • Simple, User-Friendly PC Interface. Use the simple interface to upload test results to a PC or download previous data and nameplate configurations.
  • Rugged and Reliable. Has outstanding durability for field use and produces high-quality results with high repeatability, allowing for rapid and reliable decisions.
  • Wireless Synchronization. The DFA100 uses a wireless synchronization module for timing PD and mechanical activity against the power system frequency.